013-3-335 REV. B
(VISIBLE FOR 15 SEC. AFTER EVENT)
(VISIBLE FOR 15 SEC. AFTER EVENT)
(BLINKING @ 1 SEC. RATE)
O.K.
CODES D’ANOMALIE
DEL 7 DEL 6 ÉTAT
OFF OFF SYSTÈME CORRECT
OFF ON DÉFAILLANCE DE L’AUTODIAGNOSTIC
(CLIGNOTEMENT TOUTES LES SECONDES)
ON OFF INTERVERROUILLAGE DE SÛRETÉ DE L’ONDULEUR
(VISIBLE PENDANT LES 15 SECONDES QUI SUIVENT L’ÉVÉNEMENT)
ON ON TORCHE BLOQUÉE EN POSITION OUVERTE
(VISIBLE PENDANT LES 15 SECONDES QUI SUIVENT L’ÉVÉNEMENT)
N
O
DE RÉFÉRENCE DE LA SOURCE DE COURANT 086000 086007
TENSION D'ENTRÉE 400 V c.a., 3É" 230 V c.a., 3É"
NOMBRE DE TOURS DU CORDON
D’ALIMENTATION SUR LE TORE 3 2
DISJONCTEUR (S1) 003193 003195
CI DU FILTRE EMI (PCB1) 041566 041587
PONT D’ENTRÉE (D1) 109090 109134
CIRCUIT IMPRIMÉ D’ALIMENTATION (PCB2) 041568 041607
SELF DU FACTEUR DE PUISSANCE (L1) 014231 014241
TRANSFORMATEUR DE PUISSANCE (T2) 014234 014238
CONDENSATEURS SUR LE CI D’ALIMENTATION 009999/2 109118/2
MODULE IGBT (Q2) 109079 109061
CHRONOGRAMME 013333 013333
V c.c. 540 310
CI DE COMMANDE
PCB3
PUISSANCE
AMORÇAGE
DEL6 DEL7 DEL8
COURANT
NORMAL
BASSE TENSION
BASSE PRESSION
BUSE DE PROTECTION
ENLEVÉE
TEMPÉRATURE EXCESSIVE
CÂBLE RUBAN 26 POSITIONS
AVANT
Schéma de câblage, 230 et 400 V de la Powermax600 page 9