HYPERTHERM SENSOR™ OHC
A
UTOMATED OXY HEIGHT CONTROL
O
PERATION & SET UP GUIDE
Making people and machines more productive through process Automation
Vista de pagina 0
1 2 3 4 5 6 ... 25 26

Indice de contenidos

Pagina 1 - OXY HEIGHT CONTROL

HYPERTHERM SENSOR™ OHC AUTOMATED OXY HEIGHT CONTROL OPERATION & SET UP GUIDE Making people and machin

Pagina 2

6 Sensor OHC Operation and Set Up Guide Control Unit Front Height Set Point AdjustSet Up & Calibration Access Panel Power Indicator In

Pagina 3

Section 1: Overview 7 Control Unit Bottom Power & Motor Ground Limit Switches Control Interface 6 Amp FuseCapacitive Sensor

Pagina 4

8 Sensor OHC Operation and Set Up Guide Sensor and Mounting Isolator Mounting Isolator Spring Breakaway Capacitive Sensor Ring

Pagina 5 - High Voltages

Section 2: Operation 9 Section 2: Operation Operation Modes The two basic modes of operation are “Automatic” and “Manual”. Note: The control unit

Pagina 6

10 Sensor OHC Operation and Set Up Guide Error Conditions Error Indications The red ERROR LED indicates abnormal conditions by flashing an error cod

Pagina 7 - Section 1: Overview

Section 3: Installation and Set Up 11 Section 3: Installation and Set Up Installation Sensor Mounting The sensor connection is thru the coax cable

Pagina 8 - System Features*

12 Sensor OHC Operation and Set Up Guide Connectors Wire the unit as shown with reference to the following figures. A standard mating connector kit

Pagina 9

Section 3: Installation and Set Up 13 Limit Switch The lifter upper and lower limit switches are connected to the 9 pin “D” connector. These swit

Pagina 10 - Control Unit Front

14 Sensor OHC Operation and Set Up Guide This second external height set point could be useful to provide an independent pierce or preheat height. B

Pagina 11 - Control Unit Bottom

Section 3: Installation and Set Up 15 Standard Wiring Installation MINPIN4REMOTE HEIGHT ADJPIN14PIN2PIN3PIN11PIN8PIN6PIN 6ERROR OUTPUTLOWER LIMI

Pagina 12 - Sensor and Mounting Isolator

DISCLAIMER The information in this document is subject to change without notice and should not be construe

Pagina 13 - Section 2: Operation

16 Sensor OHC Operation and Set Up Guide IO Interfacing The attached figure shows the details of connecting the IO to external switches, relays, tran

Pagina 14 - Error Conditions

Section 3: Installation and Set Up 17 DIP Switch Setup SW1 SW2 SW3 Sensor Cable Length on on on cable length = 500 mm off on on

Pagina 15 - Installation

18 Sensor OHC Operation and Set Up Guide Calibration Procedure Calibration Instructions 1) Install the torch and sensor ring with torch tip aligne

Pagina 16

Section 3: Installation and Set Up 19 Component List Optional Sensor Cables Part Number Description CONN-0141 MATING CONNECTOR KIT CABL-0163 A

Pagina 17

20 Sensor OHC Operation and Set Up Guide Connector Kit (CONN-141) Components

Pagina 19

Printed in the USA MANU-0044

Pagina 20 - IO Interfacing

Table of Contents SAFETY ...

Pagina 22 - Calibration Procedure

Safety 1 Safety Read This Manual Read and understand this instructional manual, the cutting machine manuals, and your employer’s safety practices.

Pagina 23 - Component List

2 Sensor OHC Operation and Set Up Guide

Pagina 24

Section 1: Overview 3 Section 1: Overview Introduction One of the most important parameters in Oxy Torch cutting is consistent torch tip to plate

Pagina 25

4 Sensor OHC Operation and Set Up Guide Description and Features System Features* Compatible Motors DC shunt 24VDC, 2 Amps to

Pagina 26

Section 1: Overview 5 Hardware Specifications Main Power Supply: 24 Vdc +/- 10%, 50/60 Hz Compatible Lifter Motors: DC shunt motor 24Vdc, 2 Am